1200字范文,内容丰富有趣,写作的好帮手!
1200字范文 > 小电阻接地 small resistance grounding英语短句 例句大全

小电阻接地 small resistance grounding英语短句 例句大全

时间:2021-12-02 08:25:40

相关推荐

小电阻接地 small resistance grounding英语短句 例句大全

小电阻接地,small resistance grounding

1)small resistance grounding小电阻接地

1.The grounding current value,fault current feature of thesmall resistance grounding system and ranges of zero sequence current protection when grounding transformer is connected to different position are analyzed.介绍了小电阻接地系统的接地变压器接于不同位置时的接地电流值和故障电流的特征,分析了零序电流保护范围的不同。

2.The paper analyzed the modes of neutral effective grounding and neutral non-effective grounding, and compared two modes ofsmall resistance grounding and arc suppression coil grounding.对中性点有效接地方式和中性点非有效接地方式加以比较分析,并分别以具有代表性且应用比较广泛的经小电阻接地和经消弧线圈接地2种方式进行了比较。

英文短句/例句

1.The Layout of Current Transformer of 10 kV Micro-ohm Resistance Grounding System10kV小电阻接地系统电流互感器配置

2.Discussion about Substation Grounding for Medium-voltage Low-resistance Grounding System对中压小电阻接地系统变电所接地问题的探讨

3.Discuss on Earthing Protection Scheme in Neutral Grounded with Low-resistance Distributed System中性点经小电阻接地系统接地保护方案探讨

4.Research and Calculation of Relay Protection in Low-resistance Grounding System;小电阻接地系统继电保护的研究和整定计算

5.Discussion on Grounding Way of Iron and Steel Plant"s Distribution System Neutral Point Through Low Resistance浅谈钢铁企业配电系统中性点小电阻接地方式

6.New Problem of Protection in Power System Grounding with Low Resistance小电阻接地系统给继电保护带来的新问题

7.Study of a Neutral Grounding Method with an Arc Suppression Coil and a Parallel Low Resistance中性点经消弧线圈瞬时并联小电阻接地研究

8.Cause of Malfunction of Grounding Transformer Zero-sequence Current Protection in 10kV Low Resistance Grounding System10kV小电阻接地系统接地变压器零序保护误动原因分析

9.Scheme on solving Low Resistance Grounding System Overhead 10kV Distribution Line Fault Based on Automatic Switch基于自动开关的小电阻接地系统架空10kV配电线路故障处理方案

10.Influence factors and reducing methods of earth resistances影响接地电阻的因素及减小接地电阻的方法

11.Design and Optimized Selection of Earthing Resistance in Small Hydropower Station小型水力发电厂接地电阻的设计及优化

12.resistance-grounded neutral system中心点电阻接地系统

13.A Fault Line Selection Method for Small Current Neutral Grounded System by Arc Suppression Coil with Parallel Medium Resistance采用消弧线圈并联中电阻的小电流接地系统故障选线方式

14.Analysis on Grounding Resistance Reducing by Using Steel Tower 3-D Grounding Device铁塔三维接地装置降低接地电阻分析

15.The Research of Distribution System Neutral Resistance Grounding and Development of Grounding Resistors配电网中性点电阻接地方式研究及接地电阻器的开发

16.Introduction to neutral grounding and resistance grounding in distribution system配电系统中性点接地方式及电阻接地方式

17.Study of Method on Grounding Resistance Measurement with Short Electrode Wire and New Decreasing Resistance Technology;地网接地电阻短距测量方法和降阻新技术研究

18.Grounding means connecting to a lowresistance earth electrode or an excellent earthing system.接地是指与具有低电阻的接地电极或良好的接地系统相联接。

相关短句/例句

low resistance grounded system小电阻接地系统

1.Based onlow resistance grounded system of Shanghai urban district, a new grounded fault indicator for overhead network was put forward.基于上海市区10kV小电阻接地系统,提出了新型的架空线路接地故障指示器。

3)low resistance grounding system小电阻接地系统

1.Analysis of malfunction of grounding transformer s zero-sequence current protection in 10 kVlow resistance grounding system;10kV小电阻接地系统接地变压器零序电流保护误动分析

2.Discussion on zero sequence overcurrent settings for 10 kVlow resistance grounding system;10 kV小电阻接地系统零序过流定值的探讨

3.This paper introduced the fault mechanism and capacitive current calculation method of thelow resistance grounding system.介绍了小电阻接地系统的故障机理及电容电流的工程计算方法。

4)grounding via small resistance小电阻接地方式

5)grounding resistance接地电阻

1.On-line test by usinggrounding resistance meter and its anti-jamming;使用接地电阻测量仪在线测量及其抗干扰

2.High-precision Transmitter for Measurement of Grounding Resistance;一种高精度接地电阻测量变送器

6)ground resistance接地电阻

1.Ground Resistance Measurement Instrument Design with USB;基于USB接口的接地电阻测量仪设计

2.Experimental design ofground resistance measurement;测试接地电阻实验的设计

延伸阅读

电力系统中性点电阻器接地电力系统中性点电阻器接地resistance grounded of electric power systemd lanllx一tong zhongx一ngd旧nd旧nzuqll旧d-电力系统中性点电阻器接地(r esistancegrounded of ele亡trie power system)电力系统中至少有一个中性点接人电阻器与大地连接,目的是限制接地故障电流。中性点经电阻器接地可以直接消除不接地系统的两个严重缺点,即能减少弧光接地过电压的危险性,并使灵敏而有选择性的接地保护得以实现。另一方面,由于这种系统的接地电流比直接接地系统的小,对邻近通信线路的干扰也较弱。单从降低弧光过电压角度来看,电阻器阻值凡满足Re、扁(。是系统的每相对地分布电容,就可以了.弧光接地时,在电弧点燃熄灭过程中,系统积累多余的电荷,使振荡过程加剧,从而产生很高的过电压。若能使这些电荷在从电弧熄灭到重燃前的一段时间(半个工频周期)内通过中性点电阻器泄漏掉,过电压就能降低。当R。)1。森时,电弧接地引起的瞬态过二““一’,。司’一七一‘一3创(,’J’一。夕阮~~J’~HJ~J即~程与中性点不接地系统没有多大区别,而当Re(今~切’一‘”、一’~~,、,“~「刁~/、~月J”,叼~一e~记试了时,过电压就小得多了。因为线路对地电容向R。放电遵循f“放电规律,当满足尺簇东时,放电时间常~v口“~~尹柑厅’司’门~‘.f~以了“砚’~毛”J「,甲数T一3R£一立一息,当‘为半个工频周期‘-钻‘一“’、叫。一2汀’闷’/JT’一州产,川’一弄时,线路上的电荷由1降至e一号一。.35。这说明Zf“切’城耳J-“;吧1”因几汗二“一二t,口“趋肠们电荷大部分(约2/3)泄漏掉,因而不会再产生很高的振荡过电压,在规模不大的架空线路系统中接人这种电阻器后,接地电流仍然不大,仍未破坏接地电弧自行熄灭的条件。这样,此种称为高值电阻器接地的系统就可以保持不接地系统(发生接地故障但不跳闸)的优点,同时又解决了弧光接地过电压的问题。为了获得快速选择性继电保护所需的足够电流,就必须降低电阻器的电阻值。但电流越大,电阻器功率越大,设备将很笨重;同时电流太大,又将有与直接地系统类似的缺点。根据运行经验,一般采用接地故障电流入为100~1000A。阻值再小就不如用电扰器有效.有的国家是把If控制在变压器额定电流的水平。使用这种阻值较低的电阻器接地系统既消除了弧光接地过电压,又使不接地系统经常出现的由电磁式电压互感器引起的铁磁谐振不再发生。当系统规模较大,特别是有重要的用户时,因为这些用户常有备用线路.要求故障线路迅速切除,故可选用这种接地方式.根据以上考虑的中性点电阻器接地系统都不是有效接地系统。这种系统中的变压器不能采用分级绝缘(即中性点需采用全绝缘)。以上两种高值和较低值电阻器接地方式适用于不同情况的配电系统,它们具有不接地或直接接地方式的某些优点,也多少存在两种接地方式的某些缺点。对于发电机中性点电阻器接地方式还有些特殊考虑.为了避免发电机在发生绕组接地故障时将铁芯烧坏,要求使单相接地电流减小到比loA更小。

本内容不代表本网观点和政治立场,如有侵犯你的权益请联系我们处理。
网友评论
网友评论仅供其表达个人看法,并不表明网站立场。